- V53DeN is the perfect combination of high efficiency, comfort and value in a natural gas tankless water heater from Rinnai. Ideal for small to medium homes or remodels, compact, easy-to-install, reliable and perfect for outdoor locations; Rinnai products provide peace of.
- Manuals and User Guides for Rinnai C53. We have 1 Rinnai C53 manual available for free PDF download: Operation & Installation Manual Rinnai C53 Operation & Installation Manual (48 pages).
- Exploded view - cabinet exploded view - internals exploded view - internals exploded view - electrical 801 012 011 005 009 010 001 002 800 003 014 002 800 004.
Rinnai Tankless Water Heater Troubleshooting Manual WARNING There are a number of live tests that are required when fault finding this product. Extreme care should be used at all times to avoid contact with energized components inside the furnace. . Visit the Rinnai website www.rinnai.us. Call Rinnai at 1-800-621-9419 or write to Rinnai, 103 International Drive, Peachtree City, Georgia 30269 Proof of purchase is required to obtain warranty service. You can show proof of purchase with a dated sales receipt, by completing and mailing the enclosed Warranty registration card within 30.
Rinnai C53 Manual Software
12-Step Tankless Water Heater Flushing Procedure
Over time, a tankless water heater may accumulate mineral build up which can erode the walls inside your tank's heating chamber. To properly maintain and clean your tankless water heater, it’s important to flush those mineral deposits at least once a year. Follow this simple process to ensure optimal tankless water heater performance and efficiency. Please read all of the instructions before beginning, as you’ll want to have all of the necessary supplies ready for the process.
You can also watch our Water Heater Flushing Procedure video on YouTube ─
1. Turn off the power source for your tankless water heater.
- Shut off the main gas or turn off the circuit breaker for electrical devices.
2. Close (turn off) the three water valves attached to your tankless water heater.
- This prevents cold water from flowing into the water heater and hot water from coming out during the cleaning process.
- The water valves consist of a cold water valve (colored blue), a hot water valve (colored red) and a main valve that runs the water into your home.
3. Remove the purge port valve caps slowly from the purge valves located on each of the cold and hot water valves.
- The purge valves have small handles that resemble the letter 'T.'
- This procedure is done to relieve any pressure that has built inside the valves and will prevent excess hot water from shooting out during the cleaning process.
- There may be pressure when removing the purge port valve caps, so it’s vital to confirm the hot water valve is completely shut off for your safety.
- Handle each cap carefully so the rubber sealing discs stay in place. These are needed for your valves to function properly.
Rinnai C53 Manual Download
4. Attach hosing lines to each of the three valves.
- If the manufacturer of your tankless water heater did not provide hosing lines, they are available at any home repair store that sells water heaters. The hosing lines must be long enough to reach between the water heater and a bucket.
- Consult the manual provided by the tankless water heater manufacturer or contact the manufacturer directly for exact instructions regarding this procedure.
- In some cases, this procedure may require you to use a sump pump and connect hoses to discharge and flush water from the tankless water heater cold and hot water valves.
5. Open the purge port valves by twisting them perpendicular to the position of the cold and hot valves.
6. Use 4 gallons (15.1 liters) of undiluted white vinegar to clean your tankless water heater. Never use chemical solutions of any kind.
- Since your home’s drinking and bathing water mostly likely flows through your tankless water heater, using chemical cleaning solutions could be extremely harmful to your health.
7. Follow the instructions included in your manufacturer’s manual to perform the flushing and draining procedure.
- This procedure may take up to 45 minutes.
8. Once the flushing process is complete, close the purge port valves by twisting the T-shaped handles.
9. Disconnect and remove the hosing lines from each valve.
10. Replace the purge port valve caps onto the purge valves.
- Tighten the caps completely and firmly. However, take care not to over-tighten or break the rubber sealing discs inside the caps.
Rinnai C53 Manual Form
11. Refer to the manufacturer's manual for exact instructions on how to safely restart your water heater.
- This may require you to rotate and open the cold and hot water valves so they are parallel to the position of the main valve.
12. Choose a sink tap inside and turn on the hot water slowly to allow the air to pass through the pipe.
- Continue to run the water until it runs steadily without air escaping (you may recognize this by a slight sputtering sound). .
- It may take to 2 or 3 minutes for all of the air pockets to escape.
The Rinnai Continuous Flow Water Heater Fault or Error Code 14 Troubleshooting Guide
Rinnai gas continuous flow water heaters have an error code feature. If there is a fault, an error code is displayed on the system or temperature controller.
Some error codes have troubleshooting steps you can take to find and fix faults. Others do not and a technician will need to be called to resolve the problem.
Error code 14 has no troubleshooting steps and Rinnai recommends the issue be addressed by a qualified technician.
Rinnai Troubleshooting
Error code 14 indicates a remaining flame safety device. This means the flame safety device on your hot water system has been triggered and will prevent water from being heated. It is common for this error code to appear and disappear again, which can cause a great deal of frustration. In addition, there are many reasons why the flame safety device will activate. That is why a qualified technician is needed to find and fix the root cause of the problem.
Rinnai Hot Water Heaters That Display Error Code 14
- Rinnai Infinity 26 Touch
- Rinnai Infinity 26
- Rinnai Infinity 20
- Rinnai Infinity 16
- Rinnai Infinity 12
- B26
- B20
- B16
Rinnai C53 Manual Diagram
Rinnai Error Code 14 Help
Rinnai C53 Manual Instructions
Jim’s Plumbing has fully qualified and insured technicians who can resolve the error code on your Rinnai hot water system. We understand being without hot water is disruptive and inconvenient. That’s why we’re available 24/7 and will always try to have a technician to your door within an hour of your call*. Our technicians will thoroughly inspect all components of your water system to ensure error code 14 is completely rectified. Plus, we offer $0 deposit, interest free payment plans** to make payment a breeze. Just ask our friendly team about eligibility criteria! We cover all metropolitan suburbs in Adelaide, Melbourne, Perth, Sydney, Brisbane and Canberra, so contact us today.